Neuro-MS Monophasic
Transcranial Magnetic Stimulator
- high-power monophasic pulse
- extremely low electromagnetic interference
- big color screen and easy-click wheel to control parameters
- two configurations for single pulse and paired pulse
- connection to computer via USB port
Description
High Power Monophasic Pulse
Thanks to 2800 V capacitor, which is 60% more robust than our previous generation of capacitors, Neuro-MS fires more powerful monophasic pulses. It ensures good motor response at low intensities.
Extremely Low Electromagnetic Interference
Neuro-MS is used for clinical practice and research. While TMS can induce a strong electrical field, this device has a very low electromagnetic interference even during charge and discharge. Thus, you can use it during EEG or ERP recordings. The magnetic stimulator can operate with EMG recorders of most manufacturers (through trig in/out sockets). However, the maximum diagnostic capabilities can be achieved, if the device is used together with Neurosoft digital systems. Neuro-MEP.NET software supplied with Neurosoft neurophysiological systems, for example, Skybox, has integrated pre-defined protocols for wide range of TMS tests:
- motor evoked potentials (MEP);
- central motor conduction time (CMCT);
- silent period (SP);
- intracortical (ICI) and interhemispheric inhibition (IHI);
- intracortical (ICF) and interhemispheric (IHF) facilitation;
- triple stimulation test (TST);
- stimulation of phrenic nerve to study the diaphragm response.
Big Color Screen and Easy-Click Wheel to Control Parameters
All stimulation parameters are displayed at bright and sharp color built-in screen. Easy-click wheel helps to set the intensity, frequency and other parameters in a matter of seconds. Neuro-MS comes with a new set of coils that have additional controls. Right on a coil you can increase or decrease the pulse intensity and trig a pulse.
Two Configurations for Single Pulse and Paired Pulse
Magnetic stimulator comes in two configurations: for single pulse stimulation and for paired pulse stimulation (ppTMS). Paired-pulse transcranial magnetic stimulation has been shown to be a useful tool to study the excitatory and inhibitory interactions in the human motor cortex.
Connection to Computer via USB Port
Neuro-MS, as our other TMS systems, can be used together with Neurosoft neurophysiological systems. Just connect the magnetic stimulator to the computer with installed EMG or EEG software via USB port. No additional sync cables are needed. Neurosoft produces both professional EMG/NCS and TMS machines. It means that integration between TMS and EMG can be done at a very deep level. EMG software can completely control all parameters of magnetic stimulator.
The support of HL7 standard allows integrating all diagnostic Neurosoft systems into the information system of a healthcare facility.-
-
-
Motor evoked potential
-
Standard protocol template to assess the short-interval intra-cortical inhibition (SICI) and facilitation (SICF)
-
Paired Associative Stimulation
-
Triple Stimulation Test
-
Figure-of-eight coil
-
-
-
-
-
Delivery Set
The delivery set can differ from country to country. Request the actual delivery set for your country from your local representative.
Neuro-MS unit (monophasic) | 1 pcs. |
End cap for Neuro-MS | 1 pcs. |
Footswitch for Neuro-MS | 1 pcs. |
FEC-03-100 figure-of-eight coil, 100 mm | 1 pcs. |
RC-03-125 big ring coil, 125 mm | 1 pcs. |
SCZ-1 mains supply cable | 1 pcs. |
USB cable (A-B) | 1 pcs. |
Screwdriver | 1 pcs. |
Unit package | 1 pcs. |
Technical Manual «Neuro-MS» | 1 pcs. |
Technical Manual «Coils for Magnetic Stimulators» | 1 pcs. |
Warranty certificate | 1 pcs. |
Options
-
Свидетельство о регистрации ПО Нейро-МС.NET
384,41 KB
-
Нейро-МС_Регистрационное удостоверение_RF_16.12.2016
4,97 MB
-
Registration Сertificate _Indonesia
2,39 MB
-
Neuro-MS_K192823
144,95 KB
-
Neuro-MS, MS/D, MSX_Certificate of compliance_Brazil_22.10.2021
2,56 MB
-
Свидетельство на товарный знак Нейро-МС
789,49 KB
-
Свидетельство на товарный знак Neuro-MS
801,59 KB