NEUROREHABILITATION
Neuro-MS/D
- proved effectiveness for rehabilitation in movement disorders*
- non-invasive and painless procedure
- reliable solution for everyday intensive work
- pre-defined treatment protocols
- breakthrough cooling system
Description
Proved effectiveness for rehabilitation in movement disorders
Transcranial magnetic stimulation (TMS) is a valuable diagnostic and therapeutic technique recommended for wide application in neurorehabilitation of patients with different disorders.
TMS can be used for recovery of motor function after spinal (injury, myelitis) or hemispherical (stroke, injury, etc.) condition.
Application: stroke, spasticity, pain, migraine, Parkinson disease, tinnitus, dystonia, essential tremor, Tourette syndrome, amyotrophic lateral sclerosis, multiple sclerosis, epilepsy, Alzheimer disease.
Non-invasive and painless procedure
If compared to electrical stimulation, transcranial magnetic stimulation does not cause painful sensations that usually occur due to activation of skin receptors under the electrode and does not require additional preparation time. At that, session lasts from just 40 seconds to 30 minutes depending on the selected protocol.
Reliable solution for everyday intensive work
Neuro-MS/D magnetic stimulators ensure deep focused stimulation of the brain providing long-term therapeutic effect.
Neuro-MS/D is not only ultimate effectiveness but a carefully thought-out performance. Neurosoft magnetic stimulators are popular choice of healthcare professionals across the world — those who value reliability, safety and time.
Pre-defined treatment protocols
Purchasing Neuro-MS/D magnetic stimulator, you get the advanced software with the set of pre-defined protocols for treatment of neurological and psychiatric disorders according to the International Federation of Clinical Neurophysiology (IFCN) recommendations. Enhanced software functionality allows you to save considerable time when performing TMS.
Breakthrough cooling system
Several thousands of pulses are usually delivered within one treatment session. The delivery of a large number of pulses may lead to coil overheating, that is why it’s important to ensure timely and effective coil cooling.
Thanks to the breakthrough cooling system, you can perform stimulation using any treatment protocol not wasting time for coil cooling between the sessions.
** Lefaucheur J. P. et al. Evidence-based guidelines on the therapeutic use of repetitive transcranial magnetic stimulation (rTMS): An update (2014–2018) // Clinical Neurophysiology. — 2020.
The support of HL7 standard allows integrating all diagnostic Neurosoft systems into the information system of a healthcare facility.-
-
Marking the stimulation spot
-
Аutomatic determination of motor threshold
-
Semiautomatic determination of motor threshold
-
Treatment course selection
-
Treatment manager
Delivery Set
The delivery set can differ from country to country. Request the actual delivery set for your country from your local representative.
Neuro-MS/D main unit | 1 pcs. |
Neuro-MS/D cooling unit | 1 pcs. |
Neuro-MS/D extra power supply unit | 1 pcs. |
End cap | 1 pcs. |
Patient cap (size 42-54) | 10 pcs. |
Patient cap (size 54-66) | 10 pcs. |
Silicone oil (canister, 3 l) | 1 pcs. |
AFEC-02-100-C cooled angulated figure-of-eight coil, 100 mm (cable 1,5 m, for Neuro-MS/D) | 1 pcs. |
Hydraulic system adapter for coil connection to Neuro-MS/D cooling unit | 2 pcs. |
Control cable cooling unit | 1 pcs. |
HV cable for extra power supply unit connection to Neuro-MS/D | 1 pcs. |
Equipotential cable | 2 pcs. |
Monitor-computer cable (220 V, 1.8 m, 3х0.75) | 1 pcs. |
SCZ-1 mains supply cable | 2 pcs. |
USB cable (A-B) | 1 pcs. |
K-3 flexible arm for coil positioning | 1 pcs. |
K-8 coil holder (trolley/wall mounted) | 1 pcs. |
T-4/А trolley | 1 pcs. |
NS4D 42006 3/8" quick connect coupling | 1 pcs. |
Technical Manual «Neuro-MS/D» | 1 pcs. |
Warranty certificate | 1 pcs. |
Technical Manual «Coils for Magnetic Stimulators» | 1 pcs. |
User manual «Neuro-MS.NET » (ver.2) | 1 pcs. |
''Transcranial Magnetic Stimulation'' handbook by Moacyr Alexandro Rosa and Marina Odebrecht Rosa | 1 pcs. |
Package | 2 pcs. |
Package | 1 pcs. |
Screwdriver | 1 pcs. |
License for Neuro-MS.NET software | 1 pcs. |
Options
-
Registration certificate_Indonesia
3,74 MB
-
Neuro-MS, MS/D, MSX_Certificate of compliance_Brazil_22.10.2021
2,56 MB
-
Australia certificate TMS MSD_MSX 30Mar2020
145,4 KB
-
Neuro-MSХ_Регистрационное удостоверение_KZ_25.01.2023
677,59 KB
-
Neuro-MSХ_регистрационное удостоверение_UZ_10.02.2023
4,62 MB
-
CloudTMS Edge OCD K233742
251,7 KB
-
NS-4 and other Israel
346 KB
-
Регистрационное удостоверение Neuro-MSХ
7,66 MB
-
Свидетельство о государственной регистрации ПО Neuro-MSX
1,24 MB
-
Декларация о соответствия Neuro-MSX_EEU_07.06.2022
112,33 KB
-
Выписка из реестра РЭП_Neuro-MSX
43,29 KB
-
Neuro-MSX_Registration certificate_Colombia
180,59 KB
-
Neuro-MSX_Registration Сertificate_Peru
375,15 KB
-
Neuro-MSX_Registration Сertificate_Taiwan
532,74 KB